NAME : request to exit motion detector
Supply Voltage : 12-24VDC or VAC .
Supply Current : 18-30mA@12-24VDC,45-80mA@12-24VAC
Dimensions : 6.53"Wx1. 57"Hx1. 53"D( 166x40x39mm)
Weight : 0. 4lb( 0. 18kg)
Relay Hold Time : 0.5-64 seconds
Operating Temperature : - 14°F to 131°F(- 10° C to 55°C)
Humidity : 0-95% non-condensing
High sensitivity Passive Infrared Sensor REQUEST-TO-EXIT Passive Infrared Sensor
Supply Voltage | 12-24VDC or VAC . | ||||
Supply Current | 18-30mA@12-24VDC,45-80mA@12-24VAC | ||||
Relay Output | 2C Contact(N.C/N.O) , 24VDC 1A Max. | ||||
Detection Type | Passive infrared | ||||
Relay Hold Time | 0.5-64 seconds | ||||
LED Indication | Red | ||||
Range | Coverage 12x5 ft at 7ft high,30x12 ft at 15 ft high(Adjustment ) | ||||
Operating Temperature | - 14°F to 131°F(- 10° C to 55°C) | ||||
Weight | 0. 4lb( 0. 18kg) | ||||
Humidity | 0-95% non-condensing | ||||
Dimensions | 6.53"Wx1. 57"Hx1. 53"D( 166x40x39mm) |
Table1: Latch Time DIP Switch Settings | ||||||
Time(sec) | Switch 1 | Switch 2 | Switch 3 | |||
0.5(Default) | OFF | OFF | OFF | |||
1 | ON | OFF | OFF | |||
2 | OFF | ON | OFF | |||
4 | ON | ON | OFF | |||
8 | OFF | OFF | ON | |||
16 | ON | OFF | ON | |||
32 | OFF | ON | ON | |||
64 | ON | ON | ON |
Table 2: LED Enable/Disable DIP Switch Settings | |||||
Switch 4 | Function | ||||
OFF | Disabled | ||||
ON | Enabled (Default) |
Table 3:Relay Mode DIP Switch Settings | |||||
Switch 5 | Function | ||||
OFF | Fail Secure | ||||
ON | Fail safe(Default) |
Table 4:Resettable/Non-resettable DIP Swithc Settings | |||||
Switch 6 | Function | ||||
OFF | Non-resettable | ||||
ON | Resettable (Default) |
TROUBLE | TROUBLE CAUSE | REMEDY | |||||||
Unit does not power up | No or low imput power. | Apply proper input voltage. | |||||||
Input power polarity reversed. | Correct wiring polarity. | ||||||||
Alarm LED does not light | LED jumper is set to “LED OFF”. | Set LED jumper to “LED ENABLE” | |||||||
Incorrect sensor mounting height | Increase / decrease mounting height | ||||||||
LED indicates light,no signal output | Incorrect wiring at output terminals | Correct wiring fault. | |||||||
Lightning damage | Replace sensor. | ||||||||
Unit continues to operate after the input power has been disconnected. | The wire to the “V-” power input was discon- nected, the “V+” is still connected. | Disconnect wire from the “V+” power input. |